Efficiency of grounding systems has to be verified periodically in the operational time. With urban development and buildings growth adjacent to power systems as HV/MV substations, it is very rare to have area around with sufficient accessibility for installing the potential and current electrodes. This paper discusses a safety criterion to verify the efficiency of a grounding system. By means of this criterion, conservative tests are suggested for both ground potential rise and touch voltage and step voltage that allow to verify the grounding systems efficiency in areas with reduced accessibility and also to monitor its evolution in the time.

Efficiency of grounding systems has to be verified periodically in the operational time. With urban development and buildings growth adjacent to power systems as HV/MV substations, it is very rare to have area around with sufficient accessibility for installing the potential and current electrodes. This paper discusses a safety criterion to verify the efficiency of a grounding system. By means of this criterion, conservative tests are suggested for both ground potential rise and touch voltage and step voltage that allow to verify the grounding systems efficiency in areas with reduced accessibility and also to monitor its evolution in the time.

Ground systems efficiency in areas with reduced accessibility / Parise, Giuseppe; Martirano, Luigi; Parise, Luigi; A., Farber; B., Katz. - ELETTRONICO. - (2014), pp. 1-5. (Intervento presentato al convegno IEEE IAS Annual meeting 2014 tenutosi a Vancouver, Canada nel 5-9 October 2014) [10.1109/IAS.2014.6978477].

Ground systems efficiency in areas with reduced accessibility

PARISE, Giuseppe;MARTIRANO, Luigi;PARISE, LUIGI;
2014

Abstract

Efficiency of grounding systems has to be verified periodically in the operational time. With urban development and buildings growth adjacent to power systems as HV/MV substations, it is very rare to have area around with sufficient accessibility for installing the potential and current electrodes. This paper discusses a safety criterion to verify the efficiency of a grounding system. By means of this criterion, conservative tests are suggested for both ground potential rise and touch voltage and step voltage that allow to verify the grounding systems efficiency in areas with reduced accessibility and also to monitor its evolution in the time.
2014
IEEE IAS Annual meeting 2014
Efficiency of grounding systems has to be verified periodically in the operational time. With urban development and buildings growth adjacent to power systems as HV/MV substations, it is very rare to have area around with sufficient accessibility for installing the potential and current electrodes. This paper discusses a safety criterion to verify the efficiency of a grounding system. By means of this criterion, conservative tests are suggested for both ground potential rise and touch voltage and step voltage that allow to verify the grounding systems efficiency in areas with reduced accessibility and also to monitor its evolution in the time.
Current auxiliary electrodes; grounding systems; grounding tests; measurements of touch and step voltages; substation grounding systems
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Ground systems efficiency in areas with reduced accessibility / Parise, Giuseppe; Martirano, Luigi; Parise, Luigi; A., Farber; B., Katz. - ELETTRONICO. - (2014), pp. 1-5. (Intervento presentato al convegno IEEE IAS Annual meeting 2014 tenutosi a Vancouver, Canada nel 5-9 October 2014) [10.1109/IAS.2014.6978477].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/567738
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact