This paper describes a novel functional body-to-sensor calibration procedure for inertial sensor-based gait analysis. The procedure is designed to be easily and autonomously performable by the subject, without the need for precise sensor positioning, or the performance of specific movements. The procedure consists in measuring the vertical axis during two static positions, and is not affected by magnetic field distortion. The procedure has been validated on ten healthy subjects using an optoelectronic system to measure the actual body-to-sensor rotation matrices. The effects of different sensor positions on each body segment, or different levels of subject inclination during the second static position of the procedure, resulted unnoticeable. The procedure showed accuracy and repeatability values less than 4 degrees for each angle except for the ankle int-external rotation (9.7 degrees, 7.2 degrees). The results demonstrate the validity of the procedure, since they are comparable with those reported for the most-adopted protocols in gait analysis. (C) 2014 Elsevier Ltd. All rights reserved.

Experimental evaluation of accuracy and repeatability of a novel body-to-sensor calibration procedure for inertial sensor-based gait analysis / Palermo, Eduardo; Rossi, Stefano; Francesca, Marini; Fabrizio, Patane; Cappa, Paolo. - In: MEASUREMENT. - ISSN 0263-2241. - STAMPA. - 52:1(2014), pp. 145-155. [10.1016/j.measurement.2014.03.004]

Experimental evaluation of accuracy and repeatability of a novel body-to-sensor calibration procedure for inertial sensor-based gait analysis

PALERMO, Eduardo;ROSSI, STEFANO;CAPPA, Paolo
2014

Abstract

This paper describes a novel functional body-to-sensor calibration procedure for inertial sensor-based gait analysis. The procedure is designed to be easily and autonomously performable by the subject, without the need for precise sensor positioning, or the performance of specific movements. The procedure consists in measuring the vertical axis during two static positions, and is not affected by magnetic field distortion. The procedure has been validated on ten healthy subjects using an optoelectronic system to measure the actual body-to-sensor rotation matrices. The effects of different sensor positions on each body segment, or different levels of subject inclination during the second static position of the procedure, resulted unnoticeable. The procedure showed accuracy and repeatability values less than 4 degrees for each angle except for the ankle int-external rotation (9.7 degrees, 7.2 degrees). The results demonstrate the validity of the procedure, since they are comparable with those reported for the most-adopted protocols in gait analysis. (C) 2014 Elsevier Ltd. All rights reserved.
2014
anatomical calibration; gait analysis; imu/mimu; inertial sensors; joint angular kinematics
01 Pubblicazione su rivista::01a Articolo in rivista
Experimental evaluation of accuracy and repeatability of a novel body-to-sensor calibration procedure for inertial sensor-based gait analysis / Palermo, Eduardo; Rossi, Stefano; Francesca, Marini; Fabrizio, Patane; Cappa, Paolo. - In: MEASUREMENT. - ISSN 0263-2241. - STAMPA. - 52:1(2014), pp. 145-155. [10.1016/j.measurement.2014.03.004]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/554878
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 133
  • ???jsp.display-item.citation.isi??? 121
social impact