Background: Laparoscopic sleeve gastrectomy (LSG) is an approved primary procedure for morbid obesity, but it is associated with serious complications, such as staple line leaks and bleeding. The objective of this study was to assess the effectiveness of staple line reinforcement (SLR) in reducing leaks and bleeding after LSG. Methods: A total of 1162 patients underwent LSG (305 males, 857 females). The mean age was 43.7 years and the mean body mass index was 48 kg/m(2). The patients were divided into 6 groups based on the type of SLR, including a no-SLR control group, with evaluation of leaking and bleeding risk and correlation of patients' characteristics with complications. Results: A total of 189 patients underwent LSG without reinforcement. The SLR method was oversewing in 476 patients, bovine pericardium in 312, synthetic polyester in 76, glycolide/trimethylene copolymer in 63, and thrombin matrix in 46. The overall leak frequency was 2.8%; higher with synthetic polyester (7.8%), 4.8% with no reinforcement, and lower with bovine pericardium strips (.3%; P < .01). Postoperative hemorrhage occurred in 35 patients (3%), with a higher frequency being observed without SLR (13.7%; P = .02). Only diabetes was a risk-factor for a leak (P < .01). Conclusion: SLR with bovine pericardium strips significantly reduced the leak risk. Postoperative bleeding was significantly lower with all SLR-methods, although there was no significant difference among the various techniques. Patients with type If diabetes had a higher risk of staple line leak after LSG. Further randomized, controlled studies are needed to improve our understanding of the efficacy of SLR during LSG. (C) 2014 American Society for Metabolic and Bariatric Surgery. All rights reserved.

Comparative use of different techniques for leak and bleeding prevention during laparoscopic sleeve gastrectomy: a multicenter study / Stefano, D’Ugo; Paolo, Gentileschi; Domenico, Benavoli; Michela, Cerci; Achille, Gaspari; Rossana Daniela, Berta; Carlo, Moretto; Rosario, Bellini; Basso, Nicola; Casella, Giovanni; Soricelli, Emanuele; Pierpaolo, Cutolo; Giampaolo, Formisano; Luigi, Angrisani; Marco, Anselmino. - In: SURGERY FOR OBESITY AND RELATED DISEASES. - ISSN 1550-7289. - (2013). [10.1016/j.soard.2013.10.018]

Comparative use of different techniques for leak and bleeding prevention during laparoscopic sleeve gastrectomy: a multicenter study

BASSO, Nicola;CASELLA, GIOVANNI;SORICELLI, EMANUELE;
2013

Abstract

Background: Laparoscopic sleeve gastrectomy (LSG) is an approved primary procedure for morbid obesity, but it is associated with serious complications, such as staple line leaks and bleeding. The objective of this study was to assess the effectiveness of staple line reinforcement (SLR) in reducing leaks and bleeding after LSG. Methods: A total of 1162 patients underwent LSG (305 males, 857 females). The mean age was 43.7 years and the mean body mass index was 48 kg/m(2). The patients were divided into 6 groups based on the type of SLR, including a no-SLR control group, with evaluation of leaking and bleeding risk and correlation of patients' characteristics with complications. Results: A total of 189 patients underwent LSG without reinforcement. The SLR method was oversewing in 476 patients, bovine pericardium in 312, synthetic polyester in 76, glycolide/trimethylene copolymer in 63, and thrombin matrix in 46. The overall leak frequency was 2.8%; higher with synthetic polyester (7.8%), 4.8% with no reinforcement, and lower with bovine pericardium strips (.3%; P < .01). Postoperative hemorrhage occurred in 35 patients (3%), with a higher frequency being observed without SLR (13.7%; P = .02). Only diabetes was a risk-factor for a leak (P < .01). Conclusion: SLR with bovine pericardium strips significantly reduced the leak risk. Postoperative bleeding was significantly lower with all SLR-methods, although there was no significant difference among the various techniques. Patients with type If diabetes had a higher risk of staple line leak after LSG. Further randomized, controlled studies are needed to improve our understanding of the efficacy of SLR during LSG. (C) 2014 American Society for Metabolic and Bariatric Surgery. All rights reserved.
2013
01 Pubblicazione su rivista::01a Articolo in rivista
Comparative use of different techniques for leak and bleeding prevention during laparoscopic sleeve gastrectomy: a multicenter study / Stefano, D’Ugo; Paolo, Gentileschi; Domenico, Benavoli; Michela, Cerci; Achille, Gaspari; Rossana Daniela, Berta; Carlo, Moretto; Rosario, Bellini; Basso, Nicola; Casella, Giovanni; Soricelli, Emanuele; Pierpaolo, Cutolo; Giampaolo, Formisano; Luigi, Angrisani; Marco, Anselmino. - In: SURGERY FOR OBESITY AND RELATED DISEASES. - ISSN 1550-7289. - (2013). [10.1016/j.soard.2013.10.018]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/536797
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 87
  • ???jsp.display-item.citation.isi??? 72
social impact