The aim of this study was to investigate whether cyclic fatigue resistance is increased for Controlled Memory (CM) Nickel-Titanium (NiTi) instruments, compared to instruments produced using traditional NiTi and instruments produced using M-Wire alloy. Two groups of NiTi endodontic instruments consisting of identical instrument sizes (constant 0.06 taper and 0.25 tip diameter and constant 0.04 taper and 0.40 tip diameter) were tested: group A compared Hyflex™ CM, Vortex ™ and ProFile ™ size 25 and 0.06 taper and group B compared Hyflex™ CM, Vortex™ and ProFile™ size 40 and 0.04 taper. 10 files from each different subgroup were tested for cyclic fatigue resistance. Mean and standard deviations of the Number of Cycles to Failure (NCF) were calculated for each group and data were statistically analysed (p < 0.05). Hyflex™ CM instruments, size 25 and 0.06 taper, and size 40 and 0.04 taper, showed a significant increase in the mean number of cycles to failure when compared with size 25 and 0.06 taper Vortex™ and ProFile™. No statistically significant difference (p > 0.05) was noted between Vortex™ and ProFile™ in the tested sizes. The new manufacturing process involving memory shape heat treatment produced new NiTi rotary files (Hyflex™ CM) significantly more resistant to fatigue than instruments produced with other proprietary methods of treatment (Vortex™) and with the traditional NiTi grinding process (ProFile™). © 2012 The Society of The Nippon Dental University.

Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study / Gianluca, Plotino; Testarelli, Luca; Dina Al, Sudani; Gianlcarlo, Pongione; Grande, NICOLA MARIA; Gambarini, Gianluca. - In: ODONTOLOGY. - ISSN 1618-1247. - 102:1(2012), pp. 1-5. [10.1007/s10266-012-0088-8]

Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study.

TESTARELLI, Luca;GRANDE, NICOLA MARIA;GAMBARINI, Gianluca
2012

Abstract

The aim of this study was to investigate whether cyclic fatigue resistance is increased for Controlled Memory (CM) Nickel-Titanium (NiTi) instruments, compared to instruments produced using traditional NiTi and instruments produced using M-Wire alloy. Two groups of NiTi endodontic instruments consisting of identical instrument sizes (constant 0.06 taper and 0.25 tip diameter and constant 0.04 taper and 0.40 tip diameter) were tested: group A compared Hyflex™ CM, Vortex ™ and ProFile ™ size 25 and 0.06 taper and group B compared Hyflex™ CM, Vortex™ and ProFile™ size 40 and 0.04 taper. 10 files from each different subgroup were tested for cyclic fatigue resistance. Mean and standard deviations of the Number of Cycles to Failure (NCF) were calculated for each group and data were statistically analysed (p < 0.05). Hyflex™ CM instruments, size 25 and 0.06 taper, and size 40 and 0.04 taper, showed a significant increase in the mean number of cycles to failure when compared with size 25 and 0.06 taper Vortex™ and ProFile™. No statistically significant difference (p > 0.05) was noted between Vortex™ and ProFile™ in the tested sizes. The new manufacturing process involving memory shape heat treatment produced new NiTi rotary files (Hyflex™ CM) significantly more resistant to fatigue than instruments produced with other proprietary methods of treatment (Vortex™) and with the traditional NiTi grinding process (ProFile™). © 2012 The Society of The Nippon Dental University.
2012
heat treatments; cyclic fatigue; niti instruments
01 Pubblicazione su rivista::01a Articolo in rivista
Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study / Gianluca, Plotino; Testarelli, Luca; Dina Al, Sudani; Gianlcarlo, Pongione; Grande, NICOLA MARIA; Gambarini, Gianluca. - In: ODONTOLOGY. - ISSN 1618-1247. - 102:1(2012), pp. 1-5. [10.1007/s10266-012-0088-8]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/485098
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 18
  • Scopus 62
  • ???jsp.display-item.citation.isi??? 44
social impact