Purpose. This study was done to compare the perfusion patterns of intrahepatic peripheral cholangiocarcinoma (IPCC) on contrast-enhanced ultrasound (CEUS) and dynamic computed tomography (CT). Materials and methods. We retrospectively reviewed 23 histologically proven cases of IPCC. All lesions were studied by CEUS with sulfur hexafluoride-filled microbubbles coated with a phospholipid capsule, and by dynamic CT. Contrast-enhancement patterns were evaluated in the arterial phase (CEUS 10-20 s after the injection; CT 25-30 s after the injection) and in the delayed phase (CEUS 120 s after the injection; CT>2-3 min after the injection). Results. Lesions were single in 18/23 cases (78%), single with nearby satellite lesions in 1/23 (4%) cases and multifocal with distant secondary lesions in 4/23 (17%) cases. Lesion diameter was 2-5 cm in 7/23 cases (30%), 5-7 cm in 13/23 cases (57%) and >7 cm in 3/23 (13%) cases. On CEUS, lesions were hypervascular in 16/23 cases (70%). On delayed-phase CEUS, 22/23 lesions (96%) were markedly hypoechoic. CT showed that the lesions were hypovascular in the arterial phase in 15/23 cases (66%) and hypervascular in 7/23 (30%) cases; one lesion (1/23; 4%) was isovascular. On delayed-phase CT, lesions were hyperdense in 17/23 cases (74%), hypodense in 5/23 (22%) cases and isodense in 1/23 (43%) cases. Conclusions. Enhancement discrepancy between delayed-phase CEUS (hypoechogenicity) and CT (hyperdensity) is common semiological findings in the study of IPCC. © 2008 Springer-Verlag.
Intrahepatic peripheral cholangiocarcinoma (IPCC): comparison between perfusion ultrasound and CT imaging / Donofrio, M; Vecchiato, F; Cantisani, V; Barbi, E; Passamonti, M; Ricci, Paolo; Malaga, R; Faccioli, N; Zamboni, G; POZZI MUCELLI, R.. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - STAMPA. - 113:(2008), pp. 76-86. [10.1007/s11547-008-0225-1]
Intrahepatic peripheral cholangiocarcinoma (IPCC): comparison between perfusion ultrasound and CT imaging.
CANTISANI V;RICCI, Paolo;
2008
Abstract
Purpose. This study was done to compare the perfusion patterns of intrahepatic peripheral cholangiocarcinoma (IPCC) on contrast-enhanced ultrasound (CEUS) and dynamic computed tomography (CT). Materials and methods. We retrospectively reviewed 23 histologically proven cases of IPCC. All lesions were studied by CEUS with sulfur hexafluoride-filled microbubbles coated with a phospholipid capsule, and by dynamic CT. Contrast-enhancement patterns were evaluated in the arterial phase (CEUS 10-20 s after the injection; CT 25-30 s after the injection) and in the delayed phase (CEUS 120 s after the injection; CT>2-3 min after the injection). Results. Lesions were single in 18/23 cases (78%), single with nearby satellite lesions in 1/23 (4%) cases and multifocal with distant secondary lesions in 4/23 (17%) cases. Lesion diameter was 2-5 cm in 7/23 cases (30%), 5-7 cm in 13/23 cases (57%) and >7 cm in 3/23 (13%) cases. On CEUS, lesions were hypervascular in 16/23 cases (70%). On delayed-phase CEUS, 22/23 lesions (96%) were markedly hypoechoic. CT showed that the lesions were hypovascular in the arterial phase in 15/23 cases (66%) and hypervascular in 7/23 (30%) cases; one lesion (1/23; 4%) was isovascular. On delayed-phase CT, lesions were hyperdense in 17/23 cases (74%), hypodense in 5/23 (22%) cases and isodense in 1/23 (43%) cases. Conclusions. Enhancement discrepancy between delayed-phase CEUS (hypoechogenicity) and CT (hyperdensity) is common semiological findings in the study of IPCC. © 2008 Springer-Verlag.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.