New immunosensors for 2-(2, 4-dichlorophenoxy) acetic acid (i.e. 2,4-D) and (2, 4, 5-trichlorophenoxy) acetic acid (i.e. 2,4,5-T) pesticide determination were developed using a non commercial antibody, hydrogen peroxide transducer and horseradish peroxidase as enzyme marker. The results show the full validity of these immunosensor devices, which were optimized using a 'competition' separation procedure. These immunosensors were also used to test pesticide recovery in common real matrices such as field grass, maize and wheat samples, for which good results were obtained. The immunosensors developed demonstrated a good selectivity versus different kinds of pesticides and may thus be considered as suitable devices for application to real matrices (LOD = 8.0 x 10(-11) mol L-1; RSD% = 5.2 for 2,4-D and LOD = 2.8 x 10(-9) mol L-1; RSD% 6.1 for 2,4,5-T).

New immunosensors for 2,4-D and 2,4,5-T pesticides determination / Tomassetti, Mauro; Martini, Elisabetta; Campanella, Luigi. - In: INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY. - ISSN 0306-7319. - STAMPA. - 92:4(2012), pp. 417-431. [10.1080/03067319.2011.592943]

New immunosensors for 2,4-D and 2,4,5-T pesticides determination

TOMASSETTI, Mauro;MARTINI, ELISABETTA;CAMPANELLA, Luigi
2012

Abstract

New immunosensors for 2-(2, 4-dichlorophenoxy) acetic acid (i.e. 2,4-D) and (2, 4, 5-trichlorophenoxy) acetic acid (i.e. 2,4,5-T) pesticide determination were developed using a non commercial antibody, hydrogen peroxide transducer and horseradish peroxidase as enzyme marker. The results show the full validity of these immunosensor devices, which were optimized using a 'competition' separation procedure. These immunosensors were also used to test pesticide recovery in common real matrices such as field grass, maize and wheat samples, for which good results were obtained. The immunosensors developed demonstrated a good selectivity versus different kinds of pesticides and may thus be considered as suitable devices for application to real matrices (LOD = 8.0 x 10(-11) mol L-1; RSD% = 5.2 for 2,4-D and LOD = 2.8 x 10(-9) mol L-1; RSD% 6.1 for 2,4,5-T).
2012
chlorinated herbicides; competition procedure; immunosensor; vegetal matrices
01 Pubblicazione su rivista::01a Articolo in rivista
New immunosensors for 2,4-D and 2,4,5-T pesticides determination / Tomassetti, Mauro; Martini, Elisabetta; Campanella, Luigi. - In: INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY. - ISSN 0306-7319. - STAMPA. - 92:4(2012), pp. 417-431. [10.1080/03067319.2011.592943]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/443373
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact