We performed a randomized study in 101 patients who underwent routine isolated coronary bypass graft surgery. In 50 cases an entire coated Carmeda circuit was used (coated group), and an uncoated circuit in the remaining 51 (uncoated group). A Medtronic Maxima oxygenator and a Biomedicus Biohead were used in all cases. Patients with coated circuits received low systemic heparinization with a heparin loading dose of 200 IU/kg, and 300 IU/kg for the control. Activated coagulation time was maintained at more than 275 s for the coated group versus more than 400 s for the uncoated one. The mean age of patients was 64.1_+9.6 for coated and 63.5.+9.7 for the uncoated group. The number of coronary grafts was 3.1_+0.7 for the coated group and 3.1___0.1 for the uncoated one. Cross-clamp and bypass times were 53+14 and 98+24 min for the coated, versus 57_15 and 104_+24 for the uncoated, group. Chest drainage was 989.4+509.5 ml

Heparin-coated circuit in coronary surgery. A clinical study / Sáenz, A; Larrañaga, G; Alvarez, L; Greco, Ernesto; Marrero, A; Lunar, M; Elósegui, C; Ubago, Jl; Gallo, I.. - In: EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY. - ISSN 1010-7940. - STAMPA. - 10(1):(1996), pp. 48-53.

Heparin-coated circuit in coronary surgery. A clinical study.

GRECO, Ernesto;
1996

Abstract

We performed a randomized study in 101 patients who underwent routine isolated coronary bypass graft surgery. In 50 cases an entire coated Carmeda circuit was used (coated group), and an uncoated circuit in the remaining 51 (uncoated group). A Medtronic Maxima oxygenator and a Biomedicus Biohead were used in all cases. Patients with coated circuits received low systemic heparinization with a heparin loading dose of 200 IU/kg, and 300 IU/kg for the control. Activated coagulation time was maintained at more than 275 s for the coated group versus more than 400 s for the uncoated one. The mean age of patients was 64.1_+9.6 for coated and 63.5.+9.7 for the uncoated group. The number of coronary grafts was 3.1_+0.7 for the coated group and 3.1___0.1 for the uncoated one. Cross-clamp and bypass times were 53+14 and 98+24 min for the coated, versus 57_15 and 104_+24 for the uncoated, group. Chest drainage was 989.4+509.5 ml
1996
01 Pubblicazione su rivista::01a Articolo in rivista
Heparin-coated circuit in coronary surgery. A clinical study / Sáenz, A; Larrañaga, G; Alvarez, L; Greco, Ernesto; Marrero, A; Lunar, M; Elósegui, C; Ubago, Jl; Gallo, I.. - In: EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY. - ISSN 1010-7940. - STAMPA. - 10(1):(1996), pp. 48-53.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/44260
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 19
social impact