Purpose; To compare ocular performance and quality of vision in pseudophakic eyes with an aspherical intraocular lens (IOL) or a conventional spherical IOL. MthQ4s: 10 patients who had unilaterally implantation of the Tecnis Z9000 IOL and 10 patients who had unilaterally implantation of the Acrysof SN6OWF IOL were included in the trial. Eight weeks afler surgery, the following parameters were assessed: uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), visual evoked potential (VEP), microperimetry, contrast sensitivity and aberrometry. Patients with IOL selections (using SRK!T- axial length> 22.0 mm) outside the range of +10.0 to +30.0 diopters (D) were excluded affer biometry using the lOLMaster (Zeiss). i{es!11frs: The mean best visual acuity (1ogMAR) was 0.04±0.07 in the Tecnis group and 0.02±0.07 in the Acrysof group (p=O,52). VEP in all spatial frequencies examined were not different between the 2 groups cosi come data obtained by microperimetry. Mesopic contrast sensitivity at high, intermediate and low spatial frequencies were not statistically different between groups. Spherical aberration (Tecnis 0,00 jim ± 0,05; Acrysof +0,15±0,07 tm) were significantly lower in patients with the TecnislOL than patients with acrysoflOL (p< 0,001 andpo,006). Conduskns Results show the Tecnis Z9000 IOL with a modified anterior aspheric surface induced significantly less higher-order aberration and spherical aberration compared with the Acrysof SN6OWF IOL.

Comparison of AcrySof SN60WF and Tecnis Z9000 Intraocular Lens in Cataract Surgery / E., Perrotta; G., Turano; Nebbioso, Marcella; M., Zuppardo; Grenga, Roberto; Vingolo, Enzo Maria. - STAMPA. - 50:(2009), p. E-Abstract 5601. (Intervento presentato al convegno ARVO tenutosi a Fort Lauderdale, Florida nel 3 maggio 2009).

Comparison of AcrySof SN60WF and Tecnis Z9000 Intraocular Lens in Cataract Surgery.

NEBBIOSO, Marcella;GRENGA, Roberto;VINGOLO, Enzo Maria
2009

Abstract

Purpose; To compare ocular performance and quality of vision in pseudophakic eyes with an aspherical intraocular lens (IOL) or a conventional spherical IOL. MthQ4s: 10 patients who had unilaterally implantation of the Tecnis Z9000 IOL and 10 patients who had unilaterally implantation of the Acrysof SN6OWF IOL were included in the trial. Eight weeks afler surgery, the following parameters were assessed: uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), visual evoked potential (VEP), microperimetry, contrast sensitivity and aberrometry. Patients with IOL selections (using SRK!T- axial length> 22.0 mm) outside the range of +10.0 to +30.0 diopters (D) were excluded affer biometry using the lOLMaster (Zeiss). i{es!11frs: The mean best visual acuity (1ogMAR) was 0.04±0.07 in the Tecnis group and 0.02±0.07 in the Acrysof group (p=O,52). VEP in all spatial frequencies examined were not different between the 2 groups cosi come data obtained by microperimetry. Mesopic contrast sensitivity at high, intermediate and low spatial frequencies were not statistically different between groups. Spherical aberration (Tecnis 0,00 jim ± 0,05; Acrysof +0,15±0,07 tm) were significantly lower in patients with the TecnislOL than patients with acrysoflOL (p< 0,001 andpo,006). Conduskns Results show the Tecnis Z9000 IOL with a modified anterior aspheric surface induced significantly less higher-order aberration and spherical aberration compared with the Acrysof SN6OWF IOL.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/439140
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact