Radiation exposure is a critical issue in multidetector CT (MDCT) particularly since fast MDCT scanners have become widely available, and the method has been proposed as a noninvasive diagnostic tool for an increasing number of clinical applications. Additional features of MDCT imaging affecting individual dose are related to the inappropriate use of scanners caused by practices such as scanning beyond the area of interest or acquiring unnecessary multiphase image sets. In order to reduce individual exposure and in accordance with the ALARA principle, several strategies have been implemented over the last few years which are based on X-ray emission or optimization of scanning parameters (i.e. mAs, kV, pitch, collimation) or which take account of the individual patient's characteristics (automatic exposure control systems and ECG-pulsing techniques for ECG-gated acquisitions). These strategies allow optimization of image quality while keeping individual exposure at the lowest level. We review here these different strategies taking into account the relationship between image noise and different scanning parameters. Data from the literature are discussed, and current technological developments are considered, including initial results of dual source and SnapShot pulse technologies which have been shown to result in a significant dose reduction in ECG-gated cardiac acquisitions without compromising image quality.

Optimizing radiation dose and image quality / Catalano, Carlo; Francone, Marco; Ascarelli, A; Mangia, M; Iacucci, I; Passariello, Roberto. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - STAMPA. - 17 Suppl 6:(2007), pp. F26-F32. [10.1007/s10406-007-0225-6]

Optimizing radiation dose and image quality

CATALANO, Carlo;FRANCONE, MARCO;PASSARIELLO, Roberto
2007

Abstract

Radiation exposure is a critical issue in multidetector CT (MDCT) particularly since fast MDCT scanners have become widely available, and the method has been proposed as a noninvasive diagnostic tool for an increasing number of clinical applications. Additional features of MDCT imaging affecting individual dose are related to the inappropriate use of scanners caused by practices such as scanning beyond the area of interest or acquiring unnecessary multiphase image sets. In order to reduce individual exposure and in accordance with the ALARA principle, several strategies have been implemented over the last few years which are based on X-ray emission or optimization of scanning parameters (i.e. mAs, kV, pitch, collimation) or which take account of the individual patient's characteristics (automatic exposure control systems and ECG-pulsing techniques for ECG-gated acquisitions). These strategies allow optimization of image quality while keeping individual exposure at the lowest level. We review here these different strategies taking into account the relationship between image noise and different scanning parameters. Data from the literature are discussed, and current technological developments are considered, including initial results of dual source and SnapShot pulse technologies which have been shown to result in a significant dose reduction in ECG-gated cardiac acquisitions without compromising image quality.
2007
.
01 Pubblicazione su rivista::01a Articolo in rivista
Optimizing radiation dose and image quality / Catalano, Carlo; Francone, Marco; Ascarelli, A; Mangia, M; Iacucci, I; Passariello, Roberto. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - STAMPA. - 17 Suppl 6:(2007), pp. F26-F32. [10.1007/s10406-007-0225-6]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/364172
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 34
  • ???jsp.display-item.citation.isi??? ND
social impact