Molecular imaging with radionuclides is a very sensitive technique because it allows to obtain images with nanomolar or picomolar concentrations. This has generated a rapid growth of interest in radionuclide imaging of small animals. Indeed radiolabeling of small molecules, antibodies, peptides and probes for gene expression enables molecular imaging in vivo, but only if a suitable imaging system is used. Detecting small tumors in humans is another important application of such techniques. In single gamma imaging, there is always a well known tradeoff between spatial resolution and sensitivity due to unavoidable collimation requirements. Limitation of the sensitivity due to collimation is well known and affects the performance of imaging systems, especially if only radiopharmaceuticals with limited uptake are available. In many cases coded aperture collimation can provide a solution, if the near field artifact effect can be eliminated or limited. At least this is the case for "small volumes" imaging, involving small animals. In this paper 3D-laminography simulations and preliminary measurements with coded aperture collimation are presented. Different masks have been designed for different applications showing the advantages of the technique in terms of sensitivity and spatial resolution. The limitations of the technique are also discussed. (c) 2006 Elsevier B.V. All rights reserved.

High-resolution, high sensitivity detectors for molecular imaging with radionuclides: The coded aperture option / F., Cusanno; E., Cisbani; S., Colilli; R., Fratoni; F., Garibaldi; F., Giuliani; M., Gricia; S., Lo Meo; M., Lucentini; F., Santavenere; R. C., Lanza; S., Majewski; Cinti, Maria Nerina; Pani, Roberto; Pellegrini, Rosanna; V., Orsolini Cencelli; F., De Notaristefani; D., Bollini; F., Navarria; G., Moschini. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 569:2 SPEC. ISS.(2006), pp. 193-196. (Intervento presentato al convegno 3rd International Conference on Imaging Technologies in Biomedical Sciences tenutosi a Milos, GREECE nel SEP 25-29, 2005) [10.1016/j.nima.2006.08.159].

High-resolution, high sensitivity detectors for molecular imaging with radionuclides: The coded aperture option

CINTI, Maria Nerina;PANI, Roberto;PELLEGRINI, Rosanna;
2006

Abstract

Molecular imaging with radionuclides is a very sensitive technique because it allows to obtain images with nanomolar or picomolar concentrations. This has generated a rapid growth of interest in radionuclide imaging of small animals. Indeed radiolabeling of small molecules, antibodies, peptides and probes for gene expression enables molecular imaging in vivo, but only if a suitable imaging system is used. Detecting small tumors in humans is another important application of such techniques. In single gamma imaging, there is always a well known tradeoff between spatial resolution and sensitivity due to unavoidable collimation requirements. Limitation of the sensitivity due to collimation is well known and affects the performance of imaging systems, especially if only radiopharmaceuticals with limited uptake are available. In many cases coded aperture collimation can provide a solution, if the near field artifact effect can be eliminated or limited. At least this is the case for "small volumes" imaging, involving small animals. In this paper 3D-laminography simulations and preliminary measurements with coded aperture collimation are presented. Different masks have been designed for different applications showing the advantages of the technique in terms of sensitivity and spatial resolution. The limitations of the technique are also discussed. (c) 2006 Elsevier B.V. All rights reserved.
2006
coded apertures; molecular imaging; radionuclides
01 Pubblicazione su rivista::01a Articolo in rivista
High-resolution, high sensitivity detectors for molecular imaging with radionuclides: The coded aperture option / F., Cusanno; E., Cisbani; S., Colilli; R., Fratoni; F., Garibaldi; F., Giuliani; M., Gricia; S., Lo Meo; M., Lucentini; F., Santavenere; R. C., Lanza; S., Majewski; Cinti, Maria Nerina; Pani, Roberto; Pellegrini, Rosanna; V., Orsolini Cencelli; F., De Notaristefani; D., Bollini; F., Navarria; G., Moschini. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 569:2 SPEC. ISS.(2006), pp. 193-196. (Intervento presentato al convegno 3rd International Conference on Imaging Technologies in Biomedical Sciences tenutosi a Milos, GREECE nel SEP 25-29, 2005) [10.1016/j.nima.2006.08.159].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/364040
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact