A new method for determining aflatoxin M1 (AFM1) in cheese by liquid chromatography–tandem mass spectrometry has been developed. Two methodologies were compared for sample extraction. The first one involves sample extraction with dichloromethane for hard, aged cheese or acetone for fresh cheese and includes a preliminary matrix solid-phase dispersion–extraction step before solid-phase extraction (SPE) clean-up by a Carbograph-4 cartridge. The second method uses a water/methanol solution (90:10, v/v) extraction at 150 ◦C before clean-up. The average recoveries of AFM1 from samples spiked at levels of 0.25–0.45 ug/kg, were 81–92% and the precision (RSD) ranged from 3 to 7% with the first method, whilst the average recoveries were 79–84%, and RSD ranged from 7 to 15% for the second method. Due to different matrix effect, the quantification limits were 0.019–0.025 g/kg in the first case and 0.048–0.143 ug/kg in the second one, depending on cheese typology.

Aflatoxin M1 determination in cheese by liquid chromatography–tandem mass spectrometry / Cavaliere, Chiara; Foglia, Patrizia; Guarino, Chiara; Marzioni, Francesca; Nazzari, Manuela; Samperi, Roberto; Lagana', Aldo. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - STAMPA. - 1135:2(2006), pp. 135-141. [10.1016/j.chroma.2006.07.048]

Aflatoxin M1 determination in cheese by liquid chromatography–tandem mass spectrometry.

CAVALIERE, CHIARA;FOGLIA, Patrizia;GUARINO, CHIARA;MARZIONI, FRANCESCA;NAZZARI, Manuela;SAMPERI, Roberto;LAGANA', Aldo
2006

Abstract

A new method for determining aflatoxin M1 (AFM1) in cheese by liquid chromatography–tandem mass spectrometry has been developed. Two methodologies were compared for sample extraction. The first one involves sample extraction with dichloromethane for hard, aged cheese or acetone for fresh cheese and includes a preliminary matrix solid-phase dispersion–extraction step before solid-phase extraction (SPE) clean-up by a Carbograph-4 cartridge. The second method uses a water/methanol solution (90:10, v/v) extraction at 150 ◦C before clean-up. The average recoveries of AFM1 from samples spiked at levels of 0.25–0.45 ug/kg, were 81–92% and the precision (RSD) ranged from 3 to 7% with the first method, whilst the average recoveries were 79–84%, and RSD ranged from 7 to 15% for the second method. Due to different matrix effect, the quantification limits were 0.019–0.025 g/kg in the first case and 0.048–0.143 ug/kg in the second one, depending on cheese typology.
2006
Aflatoxin M1; Cheese; Matrix solid-phase dispersion; Hot water extraction; Liquid chromatography; Tandem mass spectrometry
01 Pubblicazione su rivista::01a Articolo in rivista
Aflatoxin M1 determination in cheese by liquid chromatography–tandem mass spectrometry / Cavaliere, Chiara; Foglia, Patrizia; Guarino, Chiara; Marzioni, Francesca; Nazzari, Manuela; Samperi, Roberto; Lagana', Aldo. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - STAMPA. - 1135:2(2006), pp. 135-141. [10.1016/j.chroma.2006.07.048]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/358918
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 49
  • ???jsp.display-item.citation.isi??? 42
social impact