Abstract The modeling of an industrial, commercial or residential electric power systems, pursuing goals on safety, energy and costs saving, operational performances, needs innovations and new approaches to be effective. In the aim of underlining parameters as guideline and indices of rules of thumb the paper approaches their definitions as much as possible in an easy manner for a suitable use by heart. Operational parameters like cable steady current S-density and transient current T-density, load current moment μ-density are introduced to support in a new way the selection and sizing of the cross sectional area S of circuit conductors and the understanding of their behavior. The introduced load current moments and joule moments are specific parameters that can assist the system design to guarantee energy saving, reduced voltage-drops and losses, a higher value of current densities, reduced volume of conductors and other related goals of efficiencies. The ecodesign needs a cultural change of classic approaches.

Branch Circuits Ecodesign / Parise, Giuseppe; Parise, Luigi. - ELETTRONICO. - (2011), pp. 1-6. (Intervento presentato al convegno Industrial and Commercial Power Systems Technical Conference (I&CPS), 2011 IEEE tenutosi a New Port Beach,California (USA) nel May 1-5, 2011) [10.1109/ICPS.2011.5890888].

Branch Circuits Ecodesign

PARISE, Giuseppe;PARISE, LUIGI
2011

Abstract

Abstract The modeling of an industrial, commercial or residential electric power systems, pursuing goals on safety, energy and costs saving, operational performances, needs innovations and new approaches to be effective. In the aim of underlining parameters as guideline and indices of rules of thumb the paper approaches their definitions as much as possible in an easy manner for a suitable use by heart. Operational parameters like cable steady current S-density and transient current T-density, load current moment μ-density are introduced to support in a new way the selection and sizing of the cross sectional area S of circuit conductors and the understanding of their behavior. The introduced load current moments and joule moments are specific parameters that can assist the system design to guarantee energy saving, reduced voltage-drops and losses, a higher value of current densities, reduced volume of conductors and other related goals of efficiencies. The ecodesign needs a cultural change of classic approaches.
2011
Industrial and Commercial Power Systems Technical Conference (I&CPS), 2011 IEEE
Circuits Selection and Size; Design Criteria; System Distributions; Electrical Installations; Ecodesign
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Branch Circuits Ecodesign / Parise, Giuseppe; Parise, Luigi. - ELETTRONICO. - (2011), pp. 1-6. (Intervento presentato al convegno Industrial and Commercial Power Systems Technical Conference (I&CPS), 2011 IEEE tenutosi a New Port Beach,California (USA) nel May 1-5, 2011) [10.1109/ICPS.2011.5890888].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/355852
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 0
social impact