Steel bars pitting corrosion is a process that strongly jeopardises the reliability of the reinforced concrete structures exposed to chlorides. The proper treatment of uncertainties that affects geometrical, mechanical and chemical involved parameters is for some aspects still an open question because the probabilstic approach, ordinarily adopted, presents some limitations not only when few data are available to characterise involved variables but especially when some parameters are ambiguously defined, not only in terms of distribution type. In these circumstances a possibilistic approach could respresent a reasonable alternative to perform this specific reliability analysis. In the present study, the problem parameters are modelled by using a complete fuzzy criterion and a time-dependent fuzzy safety factor is defined in order to evaluate how the residual flexural resistance is greater or less than the bending moment. Moreover, the study provides a more proper mathematical analysis of the chloride penetration into concrete.

Fuzzy reliability analysis of RC structures by using an improved time-dependent model of chloride ingress / Marano, G. C.; Quaranta, Giuseppe; Sgobba, S; Greco, R; Mezzina, M.. - In: STRUCTURE AND INFRASTRUCTURE ENGINEERING. - ISSN 1573-2479. - STAMPA. - 6:1-2(2010), pp. 205-223. [10.1080/15732470802664415]

Fuzzy reliability analysis of RC structures by using an improved time-dependent model of chloride ingress

QUARANTA, GIUSEPPE;
2010

Abstract

Steel bars pitting corrosion is a process that strongly jeopardises the reliability of the reinforced concrete structures exposed to chlorides. The proper treatment of uncertainties that affects geometrical, mechanical and chemical involved parameters is for some aspects still an open question because the probabilstic approach, ordinarily adopted, presents some limitations not only when few data are available to characterise involved variables but especially when some parameters are ambiguously defined, not only in terms of distribution type. In these circumstances a possibilistic approach could respresent a reasonable alternative to perform this specific reliability analysis. In the present study, the problem parameters are modelled by using a complete fuzzy criterion and a time-dependent fuzzy safety factor is defined in order to evaluate how the residual flexural resistance is greater or less than the bending moment. Moreover, the study provides a more proper mathematical analysis of the chloride penetration into concrete.
2010
chloride penetration model, fuzzy safety factor, pitting corrosion, reliability analysis, uncertain parameters
01 Pubblicazione su rivista::01a Articolo in rivista
Fuzzy reliability analysis of RC structures by using an improved time-dependent model of chloride ingress / Marano, G. C.; Quaranta, Giuseppe; Sgobba, S; Greco, R; Mezzina, M.. - In: STRUCTURE AND INFRASTRUCTURE ENGINEERING. - ISSN 1573-2479. - STAMPA. - 6:1-2(2010), pp. 205-223. [10.1080/15732470802664415]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/345602
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact