The present work deals with the optimization and validation of a method for the quantitative simultaneous ICP determination of metals in ambient air particulate matter. The attention has been focused on the thoracic fraction (PM10) and twelve different metals were chosen on the basis of their toxicity and of their possible use as chemical tracers. The microwave acidic digestion of the samples has been performed in the presence of different reagents and under different conditions and particular attention has been paid to the optimization of the whole analytical procedure and to the evaluation of accuracy and precision related to the single operative steps. The interferences due to the reagents and to the sampling supports have also been evaluated. In addition, the analytical procedure has been checked by examining the equivalence of results related to parallel sampled filters pairs.

Determination of metals in thoracic fraction of ambient air particulate matter / P., Bruno; Canepari, Silvia; Cardarelli, Enrico; C. D., Del Cavaliere; Ghighi, Silvano. - In: ANNALI DI CHIMICA. - ISSN 0003-4592. - 90:11-12(2000), pp. 645-654. (Intervento presentato al convegno 2nd National Conference on Heavy Metals in the Envirinment and their Effects on Soils, Waters, Living Organisms and Human Health tenutosi a SASSARI, ITALY nel MAY 04-05, 2000).

Determination of metals in thoracic fraction of ambient air particulate matter

CANEPARI, Silvia;CARDARELLI, Enrico;GHIGHI, Silvano
2000

Abstract

The present work deals with the optimization and validation of a method for the quantitative simultaneous ICP determination of metals in ambient air particulate matter. The attention has been focused on the thoracic fraction (PM10) and twelve different metals were chosen on the basis of their toxicity and of their possible use as chemical tracers. The microwave acidic digestion of the samples has been performed in the presence of different reagents and under different conditions and particular attention has been paid to the optimization of the whole analytical procedure and to the evaluation of accuracy and precision related to the single operative steps. The interferences due to the reagents and to the sampling supports have also been evaluated. In addition, the analytical procedure has been checked by examining the equivalence of results related to parallel sampled filters pairs.
2000
01 Pubblicazione su rivista::01a Articolo in rivista
Determination of metals in thoracic fraction of ambient air particulate matter / P., Bruno; Canepari, Silvia; Cardarelli, Enrico; C. D., Del Cavaliere; Ghighi, Silvano. - In: ANNALI DI CHIMICA. - ISSN 0003-4592. - 90:11-12(2000), pp. 645-654. (Intervento presentato al convegno 2nd National Conference on Heavy Metals in the Envirinment and their Effects on Soils, Waters, Living Organisms and Human Health tenutosi a SASSARI, ITALY nel MAY 04-05, 2000).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/255448
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 12
social impact