In the present work a Fenton's treatment for the oxidation of a phosphorous compounds mixture, simulating a match manufacturing industry wastewater, were studied. Experimental tests were performed on three sample solutions at a phosphorus concentration of 250, 500 and 750 mg/l. In each solution an equal amount of sodium phosphite and sodium hypophosphite was dissolved. The investigation of pH, temperature and reagents ratio on the oxidation rate led to the individuation of the optimal process operating conditions. The results show that Fenton's reagent provides a powerful conversion to phosphate of the phosphorous solution. In particular at pH=3.5 and 20 degreesC a residual concentration of non oxidized phosphorus in compliance with the Italian regulation limits for industrial wastewater disposal. Tests performed on sample solution of 500 mg/l P and 750 mg/l P by adding hydrogen peroxide and bivalent iron in three sequential steps led to similar reaction efficiencies to tests carried out adding both Fenton's reagents in one step, but with a remarkably lower reagents consumption.

Oxidation of phosphorus compounds by Fenton's reagent / Petrucci, Elisabetta; DI PALMA, Luca; Merli, Carlo. - In: ANNALI DI CHIMICA. - ISSN 0003-4592. - STAMPA. - 93:11(2003), pp. 935-945.

Oxidation of phosphorus compounds by Fenton's reagent

PETRUCCI, Elisabetta;DI PALMA, Luca;MERLI, Carlo
2003

Abstract

In the present work a Fenton's treatment for the oxidation of a phosphorous compounds mixture, simulating a match manufacturing industry wastewater, were studied. Experimental tests were performed on three sample solutions at a phosphorus concentration of 250, 500 and 750 mg/l. In each solution an equal amount of sodium phosphite and sodium hypophosphite was dissolved. The investigation of pH, temperature and reagents ratio on the oxidation rate led to the individuation of the optimal process operating conditions. The results show that Fenton's reagent provides a powerful conversion to phosphate of the phosphorous solution. In particular at pH=3.5 and 20 degreesC a residual concentration of non oxidized phosphorus in compliance with the Italian regulation limits for industrial wastewater disposal. Tests performed on sample solution of 500 mg/l P and 750 mg/l P by adding hydrogen peroxide and bivalent iron in three sequential steps led to similar reaction efficiencies to tests carried out adding both Fenton's reagents in one step, but with a remarkably lower reagents consumption.
2003
fenton oxidation; phosphorous compounds; process optimization
01 Pubblicazione su rivista::01a Articolo in rivista
Oxidation of phosphorus compounds by Fenton's reagent / Petrucci, Elisabetta; DI PALMA, Luca; Merli, Carlo. - In: ANNALI DI CHIMICA. - ISSN 0003-4592. - STAMPA. - 93:11(2003), pp. 935-945.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/253334
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 15
social impact