A thermal and a kinetic analysis on the decomposition processes of a commercial drug named diamplicil (AD), obtained by an antibiotic combination of ampicillin (A) and dicloxacillin (D), have been carried out to find their thermal stability. The DSC/TG curves of this commercial drug were compared with those of its active components and an excipient, the magnesium stearate (M). Kinetic study was carried out using both isothermal and dynamic TG curves. Decomposition mechanisms for both active components and commercial drug tested were not found. The kinetic data obtained by the non-isothermal isoconversional method showed that D component causes a decrease of the kinetic stability of the active A component. Additive magnesium stearate does not decrease the stability of the two components. Moreover, storage time values at room temperature were calculated. © 2002 Published by Éditions scientifiques et médicales Elsevier SAS.

Compatibility between active components of a commercial drug / Rodante, Fabrizio; VECCHIO CIPRIOTI, Stefano; Giovanni, Catalani; Tomassetti, Mauro. - In: IL FARMACO. - ISSN 0014-827X. - 57:10(2002), pp. 833-843. [10.1016/s0014-827x(02)01303-4]

Compatibility between active components of a commercial drug

RODANTE, Fabrizio;VECCHIO CIPRIOTI, Stefano;TOMASSETTI, Mauro
2002

Abstract

A thermal and a kinetic analysis on the decomposition processes of a commercial drug named diamplicil (AD), obtained by an antibiotic combination of ampicillin (A) and dicloxacillin (D), have been carried out to find their thermal stability. The DSC/TG curves of this commercial drug were compared with those of its active components and an excipient, the magnesium stearate (M). Kinetic study was carried out using both isothermal and dynamic TG curves. Decomposition mechanisms for both active components and commercial drug tested were not found. The kinetic data obtained by the non-isothermal isoconversional method showed that D component causes a decrease of the kinetic stability of the active A component. Additive magnesium stearate does not decrease the stability of the two components. Moreover, storage time values at room temperature were calculated. © 2002 Published by Éditions scientifiques et médicales Elsevier SAS.
2002
active component; commercial drug; kinetic analysis; tg/dsc
01 Pubblicazione su rivista::01a Articolo in rivista
Compatibility between active components of a commercial drug / Rodante, Fabrizio; VECCHIO CIPRIOTI, Stefano; Giovanni, Catalani; Tomassetti, Mauro. - In: IL FARMACO. - ISSN 0014-827X. - 57:10(2002), pp. 833-843. [10.1016/s0014-827x(02)01303-4]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/249911
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 14
social impact