A 75-year-old man was referred to our hospital because of sudden thoracic pain. A saccular aneurysm of the aortic arch extending on the anterior surface of the aortic arch was found on computed tomographic arteriography. The patient was hemodynamically stable and he was programmed for a staged surgical and endovascular approach (hybrid approach),. As a first stage and in order to prevent major cardiac complications due to the overstenting of the left subclavian artery (LSA) with the occlusion of the aortocoronary bypass, the patient underwent a polytetrafluoroethylene bypass graft (GORE-TEX, W.L. Gore & Associates, Flagstaff, AZ) between the LSA and the left carotid artery. Intraoperative arteriography revealed a good patency of the left carotid-subclavian bypass and of the left internal mammary bypass on the left anterior descending artery. As a second stage the endovascular procedure was accomplished 5 days later in the operating room. A Gore TAG stent graft (W.L. Gore & Associates) was deployed in the aortic arch 20 mm proximally to the aneurysmatic segment covering the ostium of the LSA. The postoperative course was uneventful and the patient was discharged on the fifth postoperative day in good general conditions. Hybrid procedures for treatment of aneurysms of the aortic arch or of the descending thoracic aorta are a promising alternative to open surgery especially in high-risk patients, with lower early morbidity and mortality rates. Long-term effectiveness remains to be fully elucidated.

Thoracic endograft positioning and carotid-subclavian bypass grafting in a patient with a saccular aneurysm at the aortic arch / N., Valerio; F., Bucci; Redler, Adriano; Salvati, Bruno; M., Ferdani. - In: VASCULAR. - ISSN 1708-5381. - STAMPA. - 15:4(2007), pp. 221-225. [10.2310/6670.2007.00048]

Thoracic endograft positioning and carotid-subclavian bypass grafting in a patient with a saccular aneurysm at the aortic arch

REDLER, Adriano;SALVATI, Bruno;
2007

Abstract

A 75-year-old man was referred to our hospital because of sudden thoracic pain. A saccular aneurysm of the aortic arch extending on the anterior surface of the aortic arch was found on computed tomographic arteriography. The patient was hemodynamically stable and he was programmed for a staged surgical and endovascular approach (hybrid approach),. As a first stage and in order to prevent major cardiac complications due to the overstenting of the left subclavian artery (LSA) with the occlusion of the aortocoronary bypass, the patient underwent a polytetrafluoroethylene bypass graft (GORE-TEX, W.L. Gore & Associates, Flagstaff, AZ) between the LSA and the left carotid artery. Intraoperative arteriography revealed a good patency of the left carotid-subclavian bypass and of the left internal mammary bypass on the left anterior descending artery. As a second stage the endovascular procedure was accomplished 5 days later in the operating room. A Gore TAG stent graft (W.L. Gore & Associates) was deployed in the aortic arch 20 mm proximally to the aneurysmatic segment covering the ostium of the LSA. The postoperative course was uneventful and the patient was discharged on the fifth postoperative day in good general conditions. Hybrid procedures for treatment of aneurysms of the aortic arch or of the descending thoracic aorta are a promising alternative to open surgery especially in high-risk patients, with lower early morbidity and mortality rates. Long-term effectiveness remains to be fully elucidated.
2007
aortic arch aneurysms; carotid-subclavian bypass; endograft; endovascular treatment; high-risk patient; hybrid approach; left subclavian artery; supra-aortic trunk revascularization; thoracic aorta; thoracic aortic aneurysms
01 Pubblicazione su rivista::01a Articolo in rivista
Thoracic endograft positioning and carotid-subclavian bypass grafting in a patient with a saccular aneurysm at the aortic arch / N., Valerio; F., Bucci; Redler, Adriano; Salvati, Bruno; M., Ferdani. - In: VASCULAR. - ISSN 1708-5381. - STAMPA. - 15:4(2007), pp. 221-225. [10.2310/6670.2007.00048]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/233830
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact