The aim of our present work was to develop a flow-through measuring apparatus for the determination of glucose content as model system in organic media and to compare the properties of the biosensor in organic and in aqueous solutions. Glucose oxidase (GOx) enzyme was immobilized on a natural protein membrane in a thin-layer enzyme cell, made of Teflon. The enzyme cell was connected into a flow injection analyzer (FIA) system with an amperometric detector. After optimizing the system the optimal flow rate was found at 0.8mlmin-1. In this case 50-60 samples were measured per hour. Adding ferrocene monocarboxylic acid (FMCA) to acetonitrile and to 2-propanol the optimal concentration was 5mgl-1, while in the case of tetrabutylammonium-p-toluenesulfonate (TBATS) the optima were 2.7 and 8.0mgl-1, respectively. With 6% buffer in acetonitrile containing FMCA more than 100 samples could be measured with the enzyme cell without any loss of activity. Measuring the hydrogen peroxide content produced in 2-propanol, the optimal concentration of buffer solution was at about 20%. The linear measuring range was 0-0.5mM glucose in acetonitrile and 0-1.0mM in 2-propanol. Glucose concentration of oily food samples was measured and compared with results obtained by the reference UV-photometric method. The correlation between the results measured by the two methods was very good with correlation coefficient (r) as high as 0.976. © 2003 Elsevier B.V. All rights reserved.

Investigation of organic phase biosensor for measuring glucose in flow injection analysis system / N., Adanyi; M., Toth Markus; E. E., Szabo; M., Varadi; Sammartino, Maria Pia; Tomassetti, Mauro; Campanella, Luigi. - In: ANALYTICA CHIMICA ACTA. - ISSN 0003-2670. - 501:2(2004), pp. 219-225. [10.1016/j.aca.2003.09.034]

Investigation of organic phase biosensor for measuring glucose in flow injection analysis system

SAMMARTINO, Maria Pia;TOMASSETTI, Mauro;CAMPANELLA, Luigi
2004

Abstract

The aim of our present work was to develop a flow-through measuring apparatus for the determination of glucose content as model system in organic media and to compare the properties of the biosensor in organic and in aqueous solutions. Glucose oxidase (GOx) enzyme was immobilized on a natural protein membrane in a thin-layer enzyme cell, made of Teflon. The enzyme cell was connected into a flow injection analyzer (FIA) system with an amperometric detector. After optimizing the system the optimal flow rate was found at 0.8mlmin-1. In this case 50-60 samples were measured per hour. Adding ferrocene monocarboxylic acid (FMCA) to acetonitrile and to 2-propanol the optimal concentration was 5mgl-1, while in the case of tetrabutylammonium-p-toluenesulfonate (TBATS) the optima were 2.7 and 8.0mgl-1, respectively. With 6% buffer in acetonitrile containing FMCA more than 100 samples could be measured with the enzyme cell without any loss of activity. Measuring the hydrogen peroxide content produced in 2-propanol, the optimal concentration of buffer solution was at about 20%. The linear measuring range was 0-0.5mM glucose in acetonitrile and 0-1.0mM in 2-propanol. Glucose concentration of oily food samples was measured and compared with results obtained by the reference UV-photometric method. The correlation between the results measured by the two methods was very good with correlation coefficient (r) as high as 0.976. © 2003 Elsevier B.V. All rights reserved.
2004
amperometric detection; biocatalysis; catalase; cholesterol; enzyme electrode; fia system; glucose measurement; glucose oxidase; media; nonaqueous solvents; optimization; organic phase biosensor; sensor; sol-gel composite; tyrosinase
01 Pubblicazione su rivista::01a Articolo in rivista
Investigation of organic phase biosensor for measuring glucose in flow injection analysis system / N., Adanyi; M., Toth Markus; E. E., Szabo; M., Varadi; Sammartino, Maria Pia; Tomassetti, Mauro; Campanella, Luigi. - In: ANALYTICA CHIMICA ACTA. - ISSN 0003-2670. - 501:2(2004), pp. 219-225. [10.1016/j.aca.2003.09.034]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/231651
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 21
social impact