Abstract BACKGROUND & AIMS: The incidence of post-TIPS hepatic encephalopathy (HE) could be reduced by using stents with a small diameter. The aim of this study was to compare the incidence of HE and the clinical efficacy of TIPS created with 8- or 10-mm PTFE-covered stents. METHODS: Consecutive cirrhotics submitted to TIPS for variceal bleeding or refractory ascites were randomized to receive a 8- or 10-mm covered stent. As recommended by our Ethical Committee, the trial was stopped after the inclusion of 45 patients. RESULTS: The two groups were comparable for age, sex, etiology, and psychometric performance. After TIPS, the portosystemic pressure gradient was significantly higher in the 8-mm stent group (8.9+/-2.7 versus 6.5+/-2.7 mmHg; p=0.007). Consequently, the probability of remaining free of complications due to portal hypertension was significantly higher in the 10-mm than in the 8-mm stent group: 82.9% versus 41.9% at one year; log-rank test, p=0.002. In particular, the persistence of ascites with the need for repeated paracentesis was significantly more frequent in the patients treated with 8-mm stent diameter for refractory ascites (log-rank test, p=0.008). The probability of remaining free of HE was similar in both groups. Cumulative survival rate was similar in both groups. CONCLUSIONS: The use of 8-mm diameter stents for TIPS leads to a significantly less efficient control of complications of portal hypertension. HE remains an unsolved major problem after TIPS.

Clinical efficacy of transjugular intrahepatic portosystemic shunt created with covered stents with different diameters: Results of a randomized controlled trial / Riggio, Oliviero; Ridola, Lorenzo; Angeloni, Stefania; Cerini, Federica; Pasquale, Chiara; Attili, Adolfo Francesco; Fanelli, F; Merli, Manuela; Salvatori, Fm. - In: JOURNAL OF HEPATOLOGY. - ISSN 0168-8278. - STAMPA. - 53:2(2010), pp. 267-272. [10.1016/j.jhep.2010.02.033]

Clinical efficacy of transjugular intrahepatic portosystemic shunt created with covered stents with different diameters: Results of a randomized controlled trial

RIGGIO, Oliviero;RIDOLA, LORENZO;ANGELONI, STEFANIA;CERINI, FEDERICA;PASQUALE, CHIARA;ATTILI, Adolfo Francesco;MERLI, Manuela;
2010

Abstract

Abstract BACKGROUND & AIMS: The incidence of post-TIPS hepatic encephalopathy (HE) could be reduced by using stents with a small diameter. The aim of this study was to compare the incidence of HE and the clinical efficacy of TIPS created with 8- or 10-mm PTFE-covered stents. METHODS: Consecutive cirrhotics submitted to TIPS for variceal bleeding or refractory ascites were randomized to receive a 8- or 10-mm covered stent. As recommended by our Ethical Committee, the trial was stopped after the inclusion of 45 patients. RESULTS: The two groups were comparable for age, sex, etiology, and psychometric performance. After TIPS, the portosystemic pressure gradient was significantly higher in the 8-mm stent group (8.9+/-2.7 versus 6.5+/-2.7 mmHg; p=0.007). Consequently, the probability of remaining free of complications due to portal hypertension was significantly higher in the 10-mm than in the 8-mm stent group: 82.9% versus 41.9% at one year; log-rank test, p=0.002. In particular, the persistence of ascites with the need for repeated paracentesis was significantly more frequent in the patients treated with 8-mm stent diameter for refractory ascites (log-rank test, p=0.008). The probability of remaining free of HE was similar in both groups. Cumulative survival rate was similar in both groups. CONCLUSIONS: The use of 8-mm diameter stents for TIPS leads to a significantly less efficient control of complications of portal hypertension. HE remains an unsolved major problem after TIPS.
2010
Transjugular intrahepatic portosystemic shunt, Covered stents, Hepatic encephalopathy, Portal hypertension, Shunt diameter
01 Pubblicazione su rivista::01a Articolo in rivista
Clinical efficacy of transjugular intrahepatic portosystemic shunt created with covered stents with different diameters: Results of a randomized controlled trial / Riggio, Oliviero; Ridola, Lorenzo; Angeloni, Stefania; Cerini, Federica; Pasquale, Chiara; Attili, Adolfo Francesco; Fanelli, F; Merli, Manuela; Salvatori, Fm. - In: JOURNAL OF HEPATOLOGY. - ISSN 0168-8278. - STAMPA. - 53:2(2010), pp. 267-272. [10.1016/j.jhep.2010.02.033]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/229921
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 31
  • Scopus 119
  • ???jsp.display-item.citation.isi??? 104
social impact