The ECORAD collaboration aims to develop a dual compact camera for acquiring ultrasound and scintigraphic images, in order to get both morphological and functional information on the same device. A final volumetric image containing the fusion information will be provided to the user. Here we present the first simulated results of the scintigraphic camera, achieved by means of the CEANT4 program. The camera is based on a four-segment slant collimator. Each segment is coupled with a planar LaBT(3)(Ce) scintillator and to a Position Sensitive Photo-Multiplier Tube. We tested two different centroid algorithms for reconstructing the planar images. The 3D information is recovered from the planar images acquired at each position of the rotating collimator by using a simple back-projection algorithm. The proposed approach of a scintigraphic camera based on slant collimators is able to recover the location and the depth of a lesion in a very accurate way.

A dual modality ultrasound-gamma system: first preliminary results of the scintigraphic camera / S., Lo Meo; N., Lanconelli; F. L., Navarria; A., Perrotta; G., Baldazzi; D., Bollini; Pani, Roberto; Pellegrini, Rosanna; Cinti, Maria Nerina; P., Bennati; G., Moschini; P., Boccaccio; V., Orsolini Cencelli. - In: NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS. - ISSN 0920-5632. - STAMPA. - 197:1(2009), pp. 366-369. (Intervento presentato al convegno 11th Topical Seminar on Innovative Particle and Radiation Detectors tenutosi a Siena, ITALY nel OCT 01, 2008) [10.1016/j.nuclphysbps.2009.10.105].

A dual modality ultrasound-gamma system: first preliminary results of the scintigraphic camera

PANI, Roberto;PELLEGRINI, Rosanna;CINTI, Maria Nerina;
2009

Abstract

The ECORAD collaboration aims to develop a dual compact camera for acquiring ultrasound and scintigraphic images, in order to get both morphological and functional information on the same device. A final volumetric image containing the fusion information will be provided to the user. Here we present the first simulated results of the scintigraphic camera, achieved by means of the CEANT4 program. The camera is based on a four-segment slant collimator. Each segment is coupled with a planar LaBT(3)(Ce) scintillator and to a Position Sensitive Photo-Multiplier Tube. We tested two different centroid algorithms for reconstructing the planar images. The 3D information is recovered from the planar images acquired at each position of the rotating collimator by using a simple back-projection algorithm. The proposed approach of a scintigraphic camera based on slant collimators is able to recover the location and the depth of a lesion in a very accurate way.
2009
01 Pubblicazione su rivista::01a Articolo in rivista
A dual modality ultrasound-gamma system: first preliminary results of the scintigraphic camera / S., Lo Meo; N., Lanconelli; F. L., Navarria; A., Perrotta; G., Baldazzi; D., Bollini; Pani, Roberto; Pellegrini, Rosanna; Cinti, Maria Nerina; P., Bennati; G., Moschini; P., Boccaccio; V., Orsolini Cencelli. - In: NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS. - ISSN 0920-5632. - STAMPA. - 197:1(2009), pp. 366-369. (Intervento presentato al convegno 11th Topical Seminar on Innovative Particle and Radiation Detectors tenutosi a Siena, ITALY nel OCT 01, 2008) [10.1016/j.nuclphysbps.2009.10.105].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/228642
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact