Recently scintillating crystals with high light yield coupled to photodetectors with high quantum efficiency have been opening a new way to make gamma cameras with superior performances based on continuous crystals. In this work we propose the analysis of a gamma camera based on a continuous LaBr(3):Ce crystal coupled to a multi-anodes photomultiplier tube (MA-PMT.). In particular we take into account four detector configurations, different in crystal thicknesses and assembling. We utilize a new position algorithm to reduce the position non linearity affecting intrinsic spatial resolution of small FoV gamma cameras when standard Anger algorithm is applied. The experimental data are obtained scanning the detectors with 0.4 mm collimated (99m)Tc source, at 1.5 mm step. An improvement in position linearity and spatial resolution of about a factor two is obtained with the new algorithm. The best values in terms of spatial resolution were 0.90 mm, 0.95 mm and 1.80 mm for integral assembled, 4.0 mm thick and 10 mm thick LaBr(3):Ce crystal respectively.

Investigation on a small FoV gamma camera based on LaBr3:Ce continuous crystal / Pani, Roberto; Pellegrini, Rosanna; Bennati, P; Cinti, Mn; Vittorini, F; Scafe, R; LO MEO, S; Navarria, Fl; Moschini, G; Cencelli, Vo; DE NOTARISTEFANI, F.. - In: NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS. - ISSN 0920-5632. - STAMPA. - 197 (1):(2009), pp. 202-205. [10.1016/j.nuclphysbps.2009.10.067]

Investigation on a small FoV gamma camera based on LaBr3:Ce continuous crystal

PANI, Roberto;PELLEGRINI, Rosanna;
2009

Abstract

Recently scintillating crystals with high light yield coupled to photodetectors with high quantum efficiency have been opening a new way to make gamma cameras with superior performances based on continuous crystals. In this work we propose the analysis of a gamma camera based on a continuous LaBr(3):Ce crystal coupled to a multi-anodes photomultiplier tube (MA-PMT.). In particular we take into account four detector configurations, different in crystal thicknesses and assembling. We utilize a new position algorithm to reduce the position non linearity affecting intrinsic spatial resolution of small FoV gamma cameras when standard Anger algorithm is applied. The experimental data are obtained scanning the detectors with 0.4 mm collimated (99m)Tc source, at 1.5 mm step. An improvement in position linearity and spatial resolution of about a factor two is obtained with the new algorithm. The best values in terms of spatial resolution were 0.90 mm, 0.95 mm and 1.80 mm for integral assembled, 4.0 mm thick and 10 mm thick LaBr(3):Ce crystal respectively.
2009
01 Pubblicazione su rivista::01a Articolo in rivista
Investigation on a small FoV gamma camera based on LaBr3:Ce continuous crystal / Pani, Roberto; Pellegrini, Rosanna; Bennati, P; Cinti, Mn; Vittorini, F; Scafe, R; LO MEO, S; Navarria, Fl; Moschini, G; Cencelli, Vo; DE NOTARISTEFANI, F.. - In: NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS. - ISSN 0920-5632. - STAMPA. - 197 (1):(2009), pp. 202-205. [10.1016/j.nuclphysbps.2009.10.067]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/228357
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact