Context. The Planck satellite was successfully launched on May 14th 2009. We have completed the pre-launch calibration measurements of the High Frequency Instrument (HFI) on board Planck and their processing. Aims. We present the results ot the pre-launch calibration of HFI in which we have multiple objectives. First, we determine instrumental parameters that cannot be measured in-flight and predict parameters that can. Second, we take the opportunity to operate and understand the instrument under a wide range of anticipated operating conditions. Finally, we estimate the performance of the instrument built. Methods. We obtained our pre-launch calibration results by characterising the component and subsystems, then by calibrating the focal plane at IAS (Orsay) in the Saturne simulator, and later from the tests at the satellite level carried out in the CSL (Liege) cryogenic vacuum chamber. We developed models to estimate the instrument pre-launch parameters when no measurement could be performed. Results. We reliably measure the Planck-HFI instrument characteristics and behaviour, and determine the flight nominal setting of all parameters. The expected in-flight performance exceeds the requirements and is close or superior to the goal specifications.

Planck pre-launch status: HFI ground calibration / F., Pajot; P. A. R., Ade; J. L., Beney; E., Breelle; D., Broszkiewicz; P., Camus; C., Carabetian; Catalano, Andrea; A., Chardin; M., Charra; J., Charra; R., Cizeron; F., Couchot; A., Coulais; B. P., Crill; K., Dassas; J., Daubin; DE BERNARDIS, Paolo; P., De Marcillac; J. M., Delouis; F. X., Desert; P., Duret; P., Eng; C., Evesque; J. J., Fourmond; S., Francois; M., Giard; Y., Giraud Heraud; L., Guglielmi; G., Guyot; J., Haissinski; S., Henrot Versille; V., Hervier; W., Holmes; W. C., Jones; J. M., Lamarre; P., Lami; A. E., Lange; M., Lefebvre; B., Leriche; C., Leroy; J., Macias Perez; T., Maciaszek; B., Maffei; A., Mahendran; B., Mansoux; Masi, Silvia; C., Mercier; M. A., Miville Deschenes; L., Montier; C., Nicolas; F., Noviello; O., Perdereau; Piacentini, Francesco; M., Piat; S., Plaszczynski; E., Pointecouteau; R., Pons; N., Ponthieu; J. L., Puget; D., Rambaud; C., Renault; J. C., Renault; C., Rioux; I., Ristorcelli; C., Rosset; Savini, Giorgio; R., Sudiwala; J. P., Torre; M., Tristram; D., Vallee; Veneziani, Marcella; D., Yvon. - In: ASTRONOMY & ASTROPHYSICS. - ISSN 0004-6361. - STAMPA. - 520:1(2010), pp. A10/1-A10/15. [10.1051/0004-6361/200913203]

Planck pre-launch status: HFI ground calibration

CATALANO, Andrea;DE BERNARDIS, Paolo;MASI, Silvia;PIACENTINI, Francesco;SAVINI, Giorgio;VENEZIANI, MARCELLA;
2010

Abstract

Context. The Planck satellite was successfully launched on May 14th 2009. We have completed the pre-launch calibration measurements of the High Frequency Instrument (HFI) on board Planck and their processing. Aims. We present the results ot the pre-launch calibration of HFI in which we have multiple objectives. First, we determine instrumental parameters that cannot be measured in-flight and predict parameters that can. Second, we take the opportunity to operate and understand the instrument under a wide range of anticipated operating conditions. Finally, we estimate the performance of the instrument built. Methods. We obtained our pre-launch calibration results by characterising the component and subsystems, then by calibrating the focal plane at IAS (Orsay) in the Saturne simulator, and later from the tests at the satellite level carried out in the CSL (Liege) cryogenic vacuum chamber. We developed models to estimate the instrument pre-launch parameters when no measurement could be performed. Results. We reliably measure the Planck-HFI instrument characteristics and behaviour, and determine the flight nominal setting of all parameters. The expected in-flight performance exceeds the requirements and is close or superior to the goal specifications.
2010
cosmic microwave background; space vehicles: instruments; submillimeter: general
01 Pubblicazione su rivista::01a Articolo in rivista
Planck pre-launch status: HFI ground calibration / F., Pajot; P. A. R., Ade; J. L., Beney; E., Breelle; D., Broszkiewicz; P., Camus; C., Carabetian; Catalano, Andrea; A., Chardin; M., Charra; J., Charra; R., Cizeron; F., Couchot; A., Coulais; B. P., Crill; K., Dassas; J., Daubin; DE BERNARDIS, Paolo; P., De Marcillac; J. M., Delouis; F. X., Desert; P., Duret; P., Eng; C., Evesque; J. J., Fourmond; S., Francois; M., Giard; Y., Giraud Heraud; L., Guglielmi; G., Guyot; J., Haissinski; S., Henrot Versille; V., Hervier; W., Holmes; W. C., Jones; J. M., Lamarre; P., Lami; A. E., Lange; M., Lefebvre; B., Leriche; C., Leroy; J., Macias Perez; T., Maciaszek; B., Maffei; A., Mahendran; B., Mansoux; Masi, Silvia; C., Mercier; M. A., Miville Deschenes; L., Montier; C., Nicolas; F., Noviello; O., Perdereau; Piacentini, Francesco; M., Piat; S., Plaszczynski; E., Pointecouteau; R., Pons; N., Ponthieu; J. L., Puget; D., Rambaud; C., Renault; J. C., Renault; C., Rioux; I., Ristorcelli; C., Rosset; Savini, Giorgio; R., Sudiwala; J. P., Torre; M., Tristram; D., Vallee; Veneziani, Marcella; D., Yvon. - In: ASTRONOMY & ASTROPHYSICS. - ISSN 0004-6361. - STAMPA. - 520:1(2010), pp. A10/1-A10/15. [10.1051/0004-6361/200913203]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/227225
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 25
social impact