The study described in this paper focussed on the requirements of Life cycle Assessment (LCA) of HVAC system. The environmental behaviour of an HVAC system evaluated by LCA considers all the process necessary for components production, use and disposal. A database for Italian conditions was created for examining the environmental impacts of material, transport, land use and energy consumption of HVAC’s processing and management. The database is capable LCA of building services. The application of the methodology is proposed for there different heating systems i.e traditional, solar and heat pump systems for the energy requirements of residential buildings in Rome. The LCA was undertaken by means of Dutch Code SimaPro 5.0® in accordance to EcoIndicator 99. The LCA of the studies showed that the renewable energy sources (solar collectors) or high performance (heat pumps) cause low environmental damage for energy consumption but high impacts on global environmental balance of the plant production resulting from the components.

A methodology for life cycle assessment of building services / DE SANTOLI, Livio; Monetti, N; Dandrea, C.. - STAMPA. - (2005). (Intervento presentato al convegno Conference on Sustainable Building SB04 tenutosi a Kuala Lumpur nel aprile 2005).

A methodology for life cycle assessment of building services

DE SANTOLI, LIVIO;
2005

Abstract

The study described in this paper focussed on the requirements of Life cycle Assessment (LCA) of HVAC system. The environmental behaviour of an HVAC system evaluated by LCA considers all the process necessary for components production, use and disposal. A database for Italian conditions was created for examining the environmental impacts of material, transport, land use and energy consumption of HVAC’s processing and management. The database is capable LCA of building services. The application of the methodology is proposed for there different heating systems i.e traditional, solar and heat pump systems for the energy requirements of residential buildings in Rome. The LCA was undertaken by means of Dutch Code SimaPro 5.0® in accordance to EcoIndicator 99. The LCA of the studies showed that the renewable energy sources (solar collectors) or high performance (heat pumps) cause low environmental damage for energy consumption but high impacts on global environmental balance of the plant production resulting from the components.
2005
Conference on Sustainable Building SB04
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
A methodology for life cycle assessment of building services / DE SANTOLI, Livio; Monetti, N; Dandrea, C.. - STAMPA. - (2005). (Intervento presentato al convegno Conference on Sustainable Building SB04 tenutosi a Kuala Lumpur nel aprile 2005).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/205401
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact