The detection efficiency of a KLOE calorimeter prototype to neutrons of kinetic energy of 21, 46 and 174 MeV has been measured by exposing it to the neutron beam of the The Svedberg Laboratory, Uppsala. The measurement of the neutron detection efficiency of a NEllO scintillator provided a reference calibration. At the lowest trigger threshold, the ratio between the calorimeter and scintillator efficiency ranges from 2.5 to 3.2.

Measurement of the detection efficiency of the KLOE calorimeter for neutrons between 20 and 174 MeV / Gauzzi, P.; Anelli, M.; Battistoni, G.; Bertolucci, S.; Bini, C.; Branchini, P.; Curceanu, C.; De Zorzi, G.; Di Domenico, A.; Di Micco, B.; Ferrari, A.; Fiore, S.; Giovannella, S.; Happacher, F.; Iliescu, M.; Martini, M.; Miscetti, S.; Nguyen, F.; Passeri, A.; Prokofiev, A.; Sala, P.; Sciascia, B.; Sirghi, F.. - STAMPA. - (2008), pp. 321-325. (Intervento presentato al convegno Astroparticle, Particle and Space Physics, Detectors ans Medical Physics Applications tenutosi a Como; Italy nel 8-12/10/2007).

Measurement of the detection efficiency of the KLOE calorimeter for neutrons between 20 and 174 MeV

P. GAUZZI
;
C. Bini;A. Di Domenico;
2008

Abstract

The detection efficiency of a KLOE calorimeter prototype to neutrons of kinetic energy of 21, 46 and 174 MeV has been measured by exposing it to the neutron beam of the The Svedberg Laboratory, Uppsala. The measurement of the neutron detection efficiency of a NEllO scintillator provided a reference calibration. At the lowest trigger threshold, the ratio between the calorimeter and scintillator efficiency ranges from 2.5 to 3.2.
2008
Astroparticle, Particle and Space Physics, Detectors ans Medical Physics Applications
Efficiency; KLOE; Neutrons
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Measurement of the detection efficiency of the KLOE calorimeter for neutrons between 20 and 174 MeV / Gauzzi, P.; Anelli, M.; Battistoni, G.; Bertolucci, S.; Bini, C.; Branchini, P.; Curceanu, C.; De Zorzi, G.; Di Domenico, A.; Di Micco, B.; Ferrari, A.; Fiore, S.; Giovannella, S.; Happacher, F.; Iliescu, M.; Martini, M.; Miscetti, S.; Nguyen, F.; Passeri, A.; Prokofiev, A.; Sala, P.; Sciascia, B.; Sirghi, F.. - STAMPA. - (2008), pp. 321-325. (Intervento presentato al convegno Astroparticle, Particle and Space Physics, Detectors ans Medical Physics Applications tenutosi a Como; Italy nel 8-12/10/2007).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/194913
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact