Solution volume and mass measurements are an essential component of any system to control and account for nuclear materials that are processed or stored in a liquid medium, both from the Operators and the Safeguards Authorities point of view. ENEA engaged a comprehensive R&D programme and, in cooperation with National and International Organizations, undertook theoretical and experimental studies on tank volume calibration and measurements in order to fill the recognized technological gap. This paper presents the experiencesof the ENEA and the University of Rome in the field of R&D on solution volume and mass determination.
Experience of the ENEA in the field of R&D on solution volume and mass determination / Dionisi, M; Remetti, Romolo. - STAMPA. - (1993), pp. 449-452.
Experience of the ENEA in the field of R&D on solution volume and mass determination
REMETTI, Romolo
1993
Abstract
Solution volume and mass measurements are an essential component of any system to control and account for nuclear materials that are processed or stored in a liquid medium, both from the Operators and the Safeguards Authorities point of view. ENEA engaged a comprehensive R&D programme and, in cooperation with National and International Organizations, undertook theoretical and experimental studies on tank volume calibration and measurements in order to fill the recognized technological gap. This paper presents the experiencesof the ENEA and the University of Rome in the field of R&D on solution volume and mass determination.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.