The Advanced Direct 1-Step (AdD1S) is one of the most validated tools for the evaluation of Shutdown Dose Rate in complex fusion tokamak machines. The present work is built on the experience in analyzing tokamaks using prior versions of the code, where the activation analysis was limited to the first-step reactions. In the light of the neutron irradiation scenarios foreseen for fusion power reactors and the increasing importance of safety requirements, the possibility to treat the multi-step reactions introduced in the present version represents a novel and relevant development in the field. Moreover, a new Python library, PyD1S, has been developed to optimize the MCNP-FISPACT interface and data analysis. In this paper, the recent developments and the first applications are presented.

Progress in development of advanced D1S dynamic code for three-dimensional shutdown dose rate calculations / Mariano, G.; Flammini, D.; Fonnesu, N.; Moro, F.; Villari, R.. - In: FUSION ENGINEERING AND DESIGN. - ISSN 0920-3796. - 157:(2020), p. 111631. [10.1016/j.fusengdes.2020.111631]

Progress in development of advanced D1S dynamic code for three-dimensional shutdown dose rate calculations

Mariano G.;
2020

Abstract

The Advanced Direct 1-Step (AdD1S) is one of the most validated tools for the evaluation of Shutdown Dose Rate in complex fusion tokamak machines. The present work is built on the experience in analyzing tokamaks using prior versions of the code, where the activation analysis was limited to the first-step reactions. In the light of the neutron irradiation scenarios foreseen for fusion power reactors and the increasing importance of safety requirements, the possibility to treat the multi-step reactions introduced in the present version represents a novel and relevant development in the field. Moreover, a new Python library, PyD1S, has been developed to optimize the MCNP-FISPACT interface and data analysis. In this paper, the recent developments and the first applications are presented.
2020
Activation; Code development; D1S; Neutronics; Shutdown dose rate
01 Pubblicazione su rivista::01a Articolo in rivista
Progress in development of advanced D1S dynamic code for three-dimensional shutdown dose rate calculations / Mariano, G.; Flammini, D.; Fonnesu, N.; Moro, F.; Villari, R.. - In: FUSION ENGINEERING AND DESIGN. - ISSN 0920-3796. - 157:(2020), p. 111631. [10.1016/j.fusengdes.2020.111631]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1471042
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 3
social impact