The energy requalification of the existing building heritage is one of the pillars of our country energy policy . A large part of the building heritage has been built with no awarness of energy consumption issues and so the old building have critical levels of energy efficency performance in comparison with the new ones. Aiming to energy efficiency and energy saving in electrical end uses, there are wide and diversified improvement strategies, which include interventions on the building envelope and HVAC systems, with the introduction, where possible, of renewable energy sources . This topic includes the energy redevelopment of the existing public buildings park aimed at achieving a performance as close as possible to almost zero-energy buildings (nZEB). In this work the problem of indoor environmental quality of nZEB buildings is addressed, with particular attention to the appearance of Indoor Air Quality. A representative case-study of a kind of buildings of historical and architectural value (subject to protection constraints) is pointed out; this building is used as a university of the Public Administration located in the climatic band D and it can be evaluated as a high performance energy building. An air quality monitoring campaign was carried out twice, after the definition of a measurement protocol, sampling of a series of pollutants and using an algorithm for the numerical evaluation of the IAQ. This monitoring campaign made it possible to evaluate IAQ trend, resulting from a variation in the external air flow of the air handling units. At the same time, dynamic simulations were carried out, with the aim of evaluate the energy savings coming from the reduction in air flow. The results coming from case study show the possibility of achieving also significant energy savings, with slight variations in air quality, especially in a situation where the quality of the outside air is poor.

La riqualificazione energetica del patrimonio edilizio esistente è uno dei pilastri su cui si basa la politica energetica del nostro Paese. Larga parte del patrimonio edilizio è stata infatti costruita senza prendere in considerazione il problema dei consumi energetici e si presenta oggi come decisamente più energivora rispetto alle nuove costruzioni. Con l’obiettivo dell’efficienza energetica e del risparmio di energia negli usi finali elettrici, si hanno ampie e diversificate possibilità di miglioramento, che includono interventi sull’involucro edilizio e sui sistemi impiantistici, con introduzione, ove possibile, di fonti rinnovabili di energia. In questo ambito si inserisce il tema della riqualificazione energetica del parco esistente di edifici pubblici volta al raggiungimento di una prestazione in linea con quella degli edifici a energia quasi zero (nZEB). In questo lavoro viene affrontato il problema della qualità ambientale indoor degli edifici nZEB, con particolare attenzione all’aspetto della Indoor Air Quality. Il lavoro ha visto l’individuazione di un caso-studio rappresentativo della tipologia di edifici di pregio storico e architettonico (sottoposti a vincolo di tutela) della Pubblica Amministrazione, adibito ad attività universitaria sito in fascia climatica D, che possa essere considerato un edificio ad elevate prestazioni energetiche. E’ stata effettuata una doppia campagna di monitoraggio della qualità dell’aria attraverso la definizione di un protocollo di misura, con campionamento di una serie di inquinanti ritenuti rappresentativi e con predisposizione di un algoritmo per la valutazione numerica di sintesi del livello di qualità dell’aria. Tale campagna di monitoraggio ha consentito di valutare le variazioni, in termini di qualità dell’aria, conseguenti ad una variazione della portata di aria esterna elaborata dalle unità di trattamento aria. Parallelamente sono state effettuate delle simulazioni energetiche in regime dinamico, con l’obiettivo di valutare il risparmio energetico conseguente alla riduzione della portata d’aria. I risultati ottenuti per il caso studio mostrano la possibilità di raggiungere anche significativi risparmi energetici, accompagnati da lievi variazioni della qualità dell’aria.

Misure di qualità dell’aria esterna ed interna in un edificio ad elevate prestazioni in ambienti ad elevato affollamento ed aperti al pubblico di proprietà della PA per la ottimizzazione delle portate di aria di ricambio finalizzate all'efficienza energetica (Report PAR 2018) / Mancini, F.; Romeo, C.; Sferra, A. S.; Nardecchia, F.. - (2018).

Misure di qualità dell’aria esterna ed interna in un edificio ad elevate prestazioni in ambienti ad elevato affollamento ed aperti al pubblico di proprietà della PA per la ottimizzazione delle portate di aria di ricambio finalizzate all'efficienza energetica (Report PAR 2018)

F. Mancini;A. S. Sferra;F. Nardecchia
2018

Abstract

The energy requalification of the existing building heritage is one of the pillars of our country energy policy . A large part of the building heritage has been built with no awarness of energy consumption issues and so the old building have critical levels of energy efficency performance in comparison with the new ones. Aiming to energy efficiency and energy saving in electrical end uses, there are wide and diversified improvement strategies, which include interventions on the building envelope and HVAC systems, with the introduction, where possible, of renewable energy sources . This topic includes the energy redevelopment of the existing public buildings park aimed at achieving a performance as close as possible to almost zero-energy buildings (nZEB). In this work the problem of indoor environmental quality of nZEB buildings is addressed, with particular attention to the appearance of Indoor Air Quality. A representative case-study of a kind of buildings of historical and architectural value (subject to protection constraints) is pointed out; this building is used as a university of the Public Administration located in the climatic band D and it can be evaluated as a high performance energy building. An air quality monitoring campaign was carried out twice, after the definition of a measurement protocol, sampling of a series of pollutants and using an algorithm for the numerical evaluation of the IAQ. This monitoring campaign made it possible to evaluate IAQ trend, resulting from a variation in the external air flow of the air handling units. At the same time, dynamic simulations were carried out, with the aim of evaluate the energy savings coming from the reduction in air flow. The results coming from case study show the possibility of achieving also significant energy savings, with slight variations in air quality, especially in a situation where the quality of the outside air is poor.
2018
La riqualificazione energetica del patrimonio edilizio esistente è uno dei pilastri su cui si basa la politica energetica del nostro Paese. Larga parte del patrimonio edilizio è stata infatti costruita senza prendere in considerazione il problema dei consumi energetici e si presenta oggi come decisamente più energivora rispetto alle nuove costruzioni. Con l’obiettivo dell’efficienza energetica e del risparmio di energia negli usi finali elettrici, si hanno ampie e diversificate possibilità di miglioramento, che includono interventi sull’involucro edilizio e sui sistemi impiantistici, con introduzione, ove possibile, di fonti rinnovabili di energia. In questo ambito si inserisce il tema della riqualificazione energetica del parco esistente di edifici pubblici volta al raggiungimento di una prestazione in linea con quella degli edifici a energia quasi zero (nZEB). In questo lavoro viene affrontato il problema della qualità ambientale indoor degli edifici nZEB, con particolare attenzione all’aspetto della Indoor Air Quality. Il lavoro ha visto l’individuazione di un caso-studio rappresentativo della tipologia di edifici di pregio storico e architettonico (sottoposti a vincolo di tutela) della Pubblica Amministrazione, adibito ad attività universitaria sito in fascia climatica D, che possa essere considerato un edificio ad elevate prestazioni energetiche. E’ stata effettuata una doppia campagna di monitoraggio della qualità dell’aria attraverso la definizione di un protocollo di misura, con campionamento di una serie di inquinanti ritenuti rappresentativi e con predisposizione di un algoritmo per la valutazione numerica di sintesi del livello di qualità dell’aria. Tale campagna di monitoraggio ha consentito di valutare le variazioni, in termini di qualità dell’aria, conseguenti ad una variazione della portata di aria esterna elaborata dalle unità di trattamento aria. Parallelamente sono state effettuate delle simulazioni energetiche in regime dinamico, con l’obiettivo di valutare il risparmio energetico conseguente alla riduzione della portata d’aria. I risultati ottenuti per il caso studio mostrano la possibilità di raggiungere anche significativi risparmi energetici, accompagnati da lievi variazioni della qualità dell’aria.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1429098
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact