Excessive values of force on L5/S1 joint can cause work-related musculoskeletal disorders, such as low back pain. Currently, the reference solution for estimating such variables is the combination of optoelectronic system and force platform, used for calculating the bottom up inverse dynamics in laboratory settings. Here we propose and validate a novel, completely wearable solution, composed by twelve inertial measurement units and pressure insole sensors. We validate the wearable solution with respect to the output of the reference solution, with data collected simultaneously on a subject performing lifting and releasing tasks with two different loads. The results are encouraging towards the use of the wearable methodology, considering the great impact of such a solution in a real manufacturing scenario.

Validation of a novel wearable solution for measuring L5/S1 load during manual material handling tasks / Conforti, Ilaria; Mileti, Ilaria; Panariello, Dario; Caporaso, Teodorico; Grazioso, Stanislao; DEL PRETE, Zaccaria; Lanzotti, Antonio; Di Gironimo, Giuseppe; Palermo, Eduardo. - (2020), pp. 501-506. (Intervento presentato al convegno 2020 IEEE International workshop on metrology for industry 4.0 and iot, metroind 4.0 and iot 2020 tenutosi a Roma) [10.1109/MetroInd4.0IoT48571.2020.9138259].

Validation of a novel wearable solution for measuring L5/S1 load during manual material handling tasks

ilaria conforti;Ilaria Mileti;Zaccaria Del Prete;Eduardo Palermo
2020

Abstract

Excessive values of force on L5/S1 joint can cause work-related musculoskeletal disorders, such as low back pain. Currently, the reference solution for estimating such variables is the combination of optoelectronic system and force platform, used for calculating the bottom up inverse dynamics in laboratory settings. Here we propose and validate a novel, completely wearable solution, composed by twelve inertial measurement units and pressure insole sensors. We validate the wearable solution with respect to the output of the reference solution, with data collected simultaneously on a subject performing lifting and releasing tasks with two different loads. The results are encouraging towards the use of the wearable methodology, considering the great impact of such a solution in a real manufacturing scenario.
2020
2020 IEEE International workshop on metrology for industry 4.0 and iot, metroind 4.0 and iot 2020
occupational disease; ergonomics; biomechanical loads; motion analysis; wearable system
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Validation of a novel wearable solution for measuring L5/S1 load during manual material handling tasks / Conforti, Ilaria; Mileti, Ilaria; Panariello, Dario; Caporaso, Teodorico; Grazioso, Stanislao; DEL PRETE, Zaccaria; Lanzotti, Antonio; Di Gironimo, Giuseppe; Palermo, Eduardo. - (2020), pp. 501-506. (Intervento presentato al convegno 2020 IEEE International workshop on metrology for industry 4.0 and iot, metroind 4.0 and iot 2020 tenutosi a Roma) [10.1109/MetroInd4.0IoT48571.2020.9138259].
File allegati a questo prodotto
File Dimensione Formato  
Conforti_Preprint_Validation-of -a-novel_2020.pdf

solo gestori archivio

Tipologia: Documento in Pre-print (manoscritto inviato all'editore, precedente alla peer review)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 498.21 kB
Formato Adobe PDF
498.21 kB Adobe PDF   Contatta l'autore
Conforti_Validation-of-a-novel_2020.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 4.67 MB
Formato Adobe PDF
4.67 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1417251
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 8
social impact