The chiral separation of baclofen (Bac) was obtained by nano-liquid chromatography tandem mass spectrometry (nano-LC–MS/MS) using a 100 μm I.D. fused silica capillary column packed with silica particles chemically modified with vancomycin. Various experimental parameters, such as composition (buffer concentration, water content, organic modifier) and pH of the mobile phase and sample solvent were investigated for method optimization. In order to increase the sensitivity an on-column focusing procedure was applied. Acceptable separation of Bac enantiomers was obtained in less than 11 min eluting in isocratic mode, with 90:10 MeOH/water (v/v) containing 10 mM ammonium acetate at pH 4.5. These optimized experimental conditions were applied to the analysis of human plasma samples spiked with racemic mixture of Bac. The use of a Buckypaper disc as sorbent membrane allows one to recover both enantiomers with yields ≥ 65%. The method was fully validated, following the identification criteria of the European Commission Decision 2002/657/EC.

Nano-liquid chromatography for enantiomers separation of baclofen by using vancomycin silica stationary phase / D'Orazio, G.; Fanali, C.; Gentili, A.; Tagliaro, F.; Fanali, S.. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - 1605:(2019). [10.1016/j.chroma.2019.07.012]

Nano-liquid chromatography for enantiomers separation of baclofen by using vancomycin silica stationary phase

Gentili A.;
2019

Abstract

The chiral separation of baclofen (Bac) was obtained by nano-liquid chromatography tandem mass spectrometry (nano-LC–MS/MS) using a 100 μm I.D. fused silica capillary column packed with silica particles chemically modified with vancomycin. Various experimental parameters, such as composition (buffer concentration, water content, organic modifier) and pH of the mobile phase and sample solvent were investigated for method optimization. In order to increase the sensitivity an on-column focusing procedure was applied. Acceptable separation of Bac enantiomers was obtained in less than 11 min eluting in isocratic mode, with 90:10 MeOH/water (v/v) containing 10 mM ammonium acetate at pH 4.5. These optimized experimental conditions were applied to the analysis of human plasma samples spiked with racemic mixture of Bac. The use of a Buckypaper disc as sorbent membrane allows one to recover both enantiomers with yields ≥ 65%. The method was fully validated, following the identification criteria of the European Commission Decision 2002/657/EC.
2019
baclofen; buckypaper; carbon nanotubes; chiral; enantiomers; nano-liquid chromatography
01 Pubblicazione su rivista::01a Articolo in rivista
Nano-liquid chromatography for enantiomers separation of baclofen by using vancomycin silica stationary phase / D'Orazio, G.; Fanali, C.; Gentili, A.; Tagliaro, F.; Fanali, S.. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - 1605:(2019). [10.1016/j.chroma.2019.07.012]
File allegati a questo prodotto
File Dimensione Formato  
DOrazio_Nano-liquid_2019.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 899.41 kB
Formato Adobe PDF
899.41 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1373616
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 16
social impact