The design and performance of the high-brilliance XAFS facility at BL10XU of SPring-8, aimed at rapid and sensitive measurement of X-ray absorption fine structure (XAFS), is reported. Both undulator gap and double-crystal monochromator have been successfully controlled covering a wide energy range (5-30 keV). A versatile goniometer system, consisting of two independent high-precision goniometers. is capable of polarized XAFS in fluorescence mode and surface-sensitive experiments using a grazing-incidence geometry. By sharing major components, i.e. a monolithic Ge 100-pixel array detector and a closed-cycle He cryostat, both polarized XAFS and X-ray standing wave (XSW) experiments can be performed at low temperature (15-300 K). The performance of the spectrometer has been evaluated by recording XAFS spectra in transmission mode.

Rapid and sensitive XAFS using a tunable X-ray undulator at BL10XU of SPring-8 / H., Oyanagi; M., Ishii; C. H., Lee; Saini, Naurang Lal; Y., Kuwahara; A., Saito; Y. IZUMI AND H., Hashimoto. - In: JOURNAL OF SYNCHROTRON RADIATION. - ISSN 0909-0495. - STAMPA. - 7:(2000), pp. 89-94. [10.1107/S0909049599016817]

Rapid and sensitive XAFS using a tunable X-ray undulator at BL10XU of SPring-8

SAINI, Naurang Lal;
2000

Abstract

The design and performance of the high-brilliance XAFS facility at BL10XU of SPring-8, aimed at rapid and sensitive measurement of X-ray absorption fine structure (XAFS), is reported. Both undulator gap and double-crystal monochromator have been successfully controlled covering a wide energy range (5-30 keV). A versatile goniometer system, consisting of two independent high-precision goniometers. is capable of polarized XAFS in fluorescence mode and surface-sensitive experiments using a grazing-incidence geometry. By sharing major components, i.e. a monolithic Ge 100-pixel array detector and a closed-cycle He cryostat, both polarized XAFS and X-ray standing wave (XSW) experiments can be performed at low temperature (15-300 K). The performance of the spectrometer has been evaluated by recording XAFS spectra in transmission mode.
2000
01 Pubblicazione su rivista::01a Articolo in rivista
Rapid and sensitive XAFS using a tunable X-ray undulator at BL10XU of SPring-8 / H., Oyanagi; M., Ishii; C. H., Lee; Saini, Naurang Lal; Y., Kuwahara; A., Saito; Y. IZUMI AND H., Hashimoto. - In: JOURNAL OF SYNCHROTRON RADIATION. - ISSN 0909-0495. - STAMPA. - 7:(2000), pp. 89-94. [10.1107/S0909049599016817]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/130785
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 13
social impact