Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order of tens of μm were measured on the GEM plane along with an energy resolution of 20%÷30%. The main limitation of CMOS sensors is represented by their poor information about time structure of the event. In this paper, the use of a concurrent light readout by means of a suitable photomultiplier and the acquisition of the electric signal induced on the GEM electrode are exploited to provide the necessary timing informations. The analysis of the PMT waveform allows a 3D reconstruction of each single clusters with a resolution on z of 100 μm. Moreover, from the PMT signals it is possible to obtain a fast reconstruction of the energy released within the detector with a resolution of the order of 25% even in the tens of keV range useful, for example, for triggering purpose.

Combined readout of a triple-GEM detector / Cavoto, G.; Antochi, V. C.; Voena, C. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 13:5(2018), pp. P05001-P05001. [10.1088/1748-0221/13/05/P05001]

Combined readout of a triple-GEM detector

Cavoto, G.
Membro del Collaboration Group
;
Antochi, V. C.
Membro del Collaboration Group
;
voena, C
Membro del Collaboration Group
2018

Abstract

Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order of tens of μm were measured on the GEM plane along with an energy resolution of 20%÷30%. The main limitation of CMOS sensors is represented by their poor information about time structure of the event. In this paper, the use of a concurrent light readout by means of a suitable photomultiplier and the acquisition of the electric signal induced on the GEM electrode are exploited to provide the necessary timing informations. The analysis of the PMT waveform allows a 3D reconstruction of each single clusters with a resolution on z of 100 μm. Moreover, from the PMT signals it is possible to obtain a fast reconstruction of the energy released within the detector with a resolution of the order of 25% even in the tens of keV range useful, for example, for triggering purpose.
2018
dE/dx detectors; Particle tracking detectors (Gaseous detectors); Time projection chambers; Instrumentation; Mathematical Physics
01 Pubblicazione su rivista::01a Articolo in rivista
Combined readout of a triple-GEM detector / Cavoto, G.; Antochi, V. C.; Voena, C. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 13:5(2018), pp. P05001-P05001. [10.1088/1748-0221/13/05/P05001]
File allegati a questo prodotto
File Dimensione Formato  
Antochi_Combined_2018.pdf

solo gestori archivio

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.02 MB
Formato Adobe PDF
2.02 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1176443
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 16
social impact